| Nguvu za farasi: | |
|---|---|
| Ugavi wa umeme: | |
| Kilainishi: | |
| kiolesura: | |
| Vifaa vya hiari: | |
| Upatikanaji: | |
| Kiasi: | |
DM34-DM200
DMZL
Vibandishi vya kusogeza hutumia matundu yaliyowekwa/kusogeza kusongesha ili kubana jokofu, kutoa utendakazi tulivu (<55dB), utendakazi wa juu (15% bora kuliko vitengo vinavyorudishwa), na sehemu chache zinazosogea (kupunguza urekebishaji) kuliko compressors za kawaida. Compressor ya Kusogeza MBP 2-12HP DMZL (mfululizo wa DM34-DM200) imeboreshwa kwa ajili ya kupoeza kwa kiwango kidogo (2-12 HP), na kuifanya kuwa bora kwa matumizi ya kibiashara na nyepesi ya viwandani.
Maonyesho ya vinywaji vya kaunta na vipoeza vya vitafunio vinahitaji vibandiko fupi na tulivu. Mfululizo wa DM34-DM200' nyayo ndogo (242x242x415mm) hutoshea chini ya vihesabio, huku utendakazi wake wa <55dB huepuka kusumbua wateja. Ufanisi wake wa nishati pia hupunguza gharama za umeme kwa $200/mwaka kwa kila kitengo dhidi ya vibambo vinavyorudishwa.
Ofisi, mikahawa, na maduka ya rejareja (50-500 sq. ft.) yanahitaji mifumo ya AC tani 1-5. Mfululizo wa DM34-DM200' kusongesha kwa axial/radial hushughulikia kushuka kwa nguvu kwa umeme (kawaida katika maeneo ya mijini), kuzuia kuzimwa kwa ghafla. Muundo wake mwepesi (26-56kg) pia hurahisisha usakinishaji kwenye paa au kuta.
Maduka ya dawa na maabara hutumia jokofu ndogo (50-200L) kuhifadhi insulini, viuavijasumu na sampuli kwa joto la 2-8°C. Msururu wa DM34-DM200 hudumisha usahihi wa ±0.5°C, kuepuka kuharibika kwa dawa. Muundo wake wa hermetic pia huzuia uchafuzi (muhimu kwa vifaa vinavyotii ISO 13485).

Visongeo vilivyowekwa na kusongeshwa vinaweza kurekebisha radially (hadi 0.5mm) na axially (hadi 0.3mm) hadi:
• Weka uchafu mdogo (huzuia uharibifu wa compressor).
• Hushughulikia jokofu kioevu (huepuka kuteleza, suala la juu na vitengo vinavyofanana).
• Dumisha muhuri mkali (≤0.1% kiwango cha uvujaji wa kila mwaka), kwa kuzingatia viwango vya mazingira.
• Visogezo vinavyosogezwa : Aloi ya alumini iliyopakwa PTFE (hupunguza msuguano kwa 30% dhidi ya mikunjo isiyofunikwa).
• Kuzaa : Shaba ya porous (kujipaka mafuta, kuondoa hitaji la mabadiliko ya mara kwa mara ya mafuta).
• Casing : Aloi ya alumini nyepesi (26-56kg) iliyopakwa unga, inayostahimili unyevunyevu kwenye mikahawa au maabara.
Compressor za jadi za kusongesha huchota mkondo wa juu wa kuanzia (hadi 150A), vivunja mzunguko wa saketi katika gridi dhaifu. Mfululizo wa DM34-DM200 hutumia upakuaji wa kuanzia ili kupunguza kuanzia sasa kwa 40% (kwa mfano, 22A dhidi ya 37A kwa muundo wa 2HP), kuhakikisha utendakazi unaotegemewa mijini au vijijini.
• Viunganishi vya Mabomba : Kusongesha au kuwasha/kufunga roto (hiari) kwa usakinishaji rahisi.
• Ugavi wa Nishati : 220V/1ph/50Hz (kwa vitengo vidogo: DM34HE/DM50HE); 380-420V/3ph/50Hz (kwa vitengo vikubwa: DM70HE-DM200HE).
• Kiato cha Crankcase : 70W (huzuia mgawanyiko wa mafuta katika mazingira ya baridi).
• Upatanifu wa Jokofu : R404A/R507A, R22 (imeboreshwa kwa ajili ya programu za MBP).
Timu yetu hutoa michoro ya 3D ili kukusaidia kujumuisha mfululizo wa DM34-DM200 katika nafasi zilizoshikana (km, onyesho la chini ya kaunta, vitengo vidogo vya AC). Pia tunapendekeza uwekaji bora zaidi ili kuongeza mtiririko wa hewa na ufanisi wa kupoeza.
Kwa mafundi wa ndani, tunasambaza vifaa vya usakinishaji na:
• Kamba za umeme zilizounganishwa kabla (ili kuepuka makosa ya nyaya).
• Adapta za mabomba (kwa soldering/flaring).
• Miongozo ya hatua kwa hatua yenye picha na video.
Hii inapunguza muda wa usakinishaji kwa 50% na gharama za wafanyikazi kwa $300 kwa kila kitengo.
• Udhamini : Miezi 12 kwa vipengele vyote; Miezi 18 ikiwa unatumia mafuta yetu yaliyopendekezwa (POE 32).
• Utatuzi wa matatizo : Nyenzo zisizolipishwa za mtandaoni ni pamoja na Maswali Yanayoulizwa Mara kwa Mara, mafunzo ya video, na mtiririko wa utatuzi wa matatizo ya kawaida (km, kushindwa kwa uanzishaji, kelele).
Tunahifadhi sehemu muhimu (vitabu, fani, fuse) katika ghala za kikanda (Marekani, Ulaya, Asia). Sehemu nyingi huletwa ndani ya siku 1-3 za kazi, na tunatoa usaidizi wa kiufundi bila malipo ili kukusaidia kubadilisha sehemu kwenye tovuti.
| Mfano | DM34HM | DM50HM | DM34HM | DM50HM | DM70HM | DM86HM | DM102HM | DM132HM | DM182HM | DM200HM | ||
| DM34HE | DM50HE | DM34HE | DM50HE | DM70HE | DM86HE | DM102HE | DM132HE | DM182HE | DM200HE | |||
| Injini | Awamu Moja | Awamu ya Tatu | ||||||||||
| Nguvu ya Majina | HP | 2 | 3 | 2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | |
| Uhamisho | m³/saa | 5.8 | 8.6 | 5.8 | 8.6 | 11.4 | 14.5 | 17.2 | 21.6 | 29.1 | 33.1 | |
| (LRA) | A | 76 | 82 | 22 | 40 | 50 | 65.5 | 74 | 115 | 118 | 121 | |
| (RLA) | A | 8.6 | 16.4 | 3.2 | 5.7 | 6.4 | 8.7 | 11.3 | 14.3 | 19.2 | 22.1 | |
| (MOC) | A | 15.2 | 23 | 15.2 | 8.1 | 9.7 | 13.5 | 16.1 | 19.8 | 26.9 | 31.1 | |
| Capacitor | 60μF | / | ||||||||||
| Nguvu ya crankcase | W | 70 | ||||||||||
| Kuunganisha bomba | Utekelezaji | Inchi | 1/2 | 7/8 | ||||||||
| Incharge | 7/8 | 1—1/8 | ||||||||||
| SIZE | 长(L) | MM | 242 | 242 | 242 | |||||||
| 宽 (W) | 242 | 242 | 242 | |||||||||
| 高 (H) | 415 | 455 | 540 | |||||||||
| Ufungaji (φ) | 190 X 190(8.5) | |||||||||||
| Malipo ya Mafuta | L | 1.4 | 2.0 | 3.4 | ||||||||
| Shinikizo la juu | 3.0 | |||||||||||
| Shinikizo la Chini | 2.0 | |||||||||||
| Uzito | Net | KG | 26 | 28 | 26 | 28 | 30 | 37 | 38 | 54 | 56 | 56 |
| Jumla | 27 | 29 | 27 | 29 | 31 | 38 | 39 | 55 | 57 | 57 | ||
R404A
| 型号Mfano | 冷凝温度℃ | 蒸发温度℃ | |||||||
| Kufupisha | Joto la kuyeyuka | ||||||||
| Halijoto | -25 | -20 | -15 | -10 | -5 | 0 | 5 | ||
| DM34HE | Q冷量(Kw) | 30 | 2.45 | 3.06 | 2.81 | 4.51 | 5.41 | 6.37 | 7.23 |
| 40 | 2.2 | 2.7 | 3.25 | 3.89 | 4.73 | 5.59 | 6.68 | ||
| 50 | 1.83 | 2.32 | 3.75 | 3.32 | 4.04 | 4.8 | 5.65 | ||
| P功率 (Kw) | 30 | 1.23 | 1.3 | 1.36 | 1.43 | 1.51 | 2.19 | 1.64 | |
| 40 | 1.45 | 1.56 | 1.62 | 1.71 | 1.77 | 1.85 | 1.92 | ||
| 50 | 1.75 | 1.85 | 1.93 | 2.03 | 2.11 | 1.56 | 2.27 | ||
| DM50HE | Q冷量(Kw) | 30 | 3.45 | 4.29 | 5.25 | 6.35 | 7.65 | 9.09 | 10.75 |
| 40 | 2.99 | 3.69 | 4.55 | 5.49 | 6.59 | 7.89 | 9.35 | ||
| 50 | 2.43 | 3.09 | 3.75 | 4.55 | 5.49 | 6.55 | 7.79 | ||
| P功率 (Kw) | 30 | 1.77 | 1.77 | 1.77 | 1.76 | 1.76 | 1.75 | 1.75 | |
| 40 | 2.24 | 2.24 | 2.24 | 2.23 | 2.22 | 2.21 | 2.19 | ||
| 50 | 2.85 | 2.83 | 2.83 | 2.82 | 2.81 | 2.79 | 2.77 | ||
| DM70HE | Q冷量(Kw) | 30 | 4.86 | 5.96 | 7.26 | 8.75 | 10.25 | 12.58 | 15.1 |
| 40 | 4.35 | 5.26 | 6.38 | 7.68 | 9.22 | 10.92 | 12.96 | ||
| 50 | 3.65 | 4.51 | 5.35 | 6.55 | 7.83 | 9.25 | 10.94 | ||
| P功率 (Kw) | 30 | 2.16 | 2.25 | 2.35 | 2.48 | 2.58 | 2.7 | 2.82 | |
| 40 | 2.57 | 2.71 | 2.78 | 2.92 | 3.05 | 3.18 | 3.28 | ||
| 50 | 3.02 | 3.18 | 3.36 | 3.52 | 3.65 | 3.78 | 3.95 | ||
| DM86HE | Q冷量(Kw) | 30 | 5.89 | 7.29 | 8.89 | 10.79 | 12.95 | 15.39 | 18.19 |
| 40 | 5.09 | 6.25 | 7.69 | 9.29 | 11.19 | 13.35 | 15.79 | ||
| 50 | 3.82 | 5.19 | 6.35 | 7.75 | 9.35 | 11.19 | 13.29 | ||
| P功率 (Kw) | 30 | 2.99 | 2.99 | 2.99 | 2.99 | 2.97 | 2.95 | 2.92 | |
| 40 | 3.75 | 3.76 | 3.76 | 3.76 | 3.76 | 3.74 | 3.71 | ||
| 50 | 4.67 | 4.67 | 4.68 | 4.68 | 4.68 | 4.67 | 4.65 | ||
| DM102HE | Q冷量(Kw) | 30 | 7.03 | 8.51 | 9.85 | 12.53 | 15.35 | 18.36 | 21.83 |
| 40 | 6.15 | 7.65 | 8.95 | 11.15 | 13.38 | 16.04 | 19.06 | ||
| 50 | 5.32 | 6.48 | 8 | 9.54 | 11.43 | 13.61 | 16.07 | ||
| P功率 (Kw) | 30 | 3.07 | 3.22 | 3.38 | 3.71 | 3.72 | 3.91 | 4.05 | |
| 40 | 3.65 | 3.75 | 4.02 | 4.35 | 4.4 | 4.61 | 4.77 | ||
| 50 | 5.93 | 4.55 | 4.78 | 5.23 | 5.51 | 5.46 | 5.64 | ||
| DM132HE | Q冷量(Kw) | 30 | 8.89 | 11.25 | 13.95 | 16.99 | 20.59 | 24.59 | 29.19 |
| 40 | 7.05 | 9.25 | 11.69 | 14.39 | 17.49 | 20.99 | 24.89 | ||
| 50 | 5.81 | 6.89 | 9.09 | 11.49 | 14.15 | 17.09 | 20.39 | ||
| P功率 (Kw) | 30 | 4.56 | 4.57 | 4.59 | 4.61 | 4.64 | 4.67 | 4.69 | |
| 40 | 5.85 | 5.79 | 5.75 | 5.75 | 5.75 | 5.75 | 5.75 | ||
| 50 | 6.55 | 7.45 | 7.35 | 7.25 | 7.21 | 7.15 | 7.15 | ||
| DM182HE | Q冷量(Kw) | 30 | 12.39 | 15.39 | 18.79 | 22.79 | 27.39 | 32.49 | 38.49 |
| 40 | 10.89 | 13.29 | 16.09 | 19.39 | 23.29 | 27.79 | 32.99 | ||
| 50 | 7.45 | 11.19 | 13.19 | 15.69 | 18.69 | 22.19 | 26.39 | ||
| P功率 (Kw) | 30 | 5.79 | 5.89 | 5.99 | 6.05 | 6.15 | 6.25 | 6.39 | |
| 40 | 7.25 | 7.29 | 7.39 | 7.45 | 7.49 | 7.59 | 7.69 | ||
| 50 | 8.48 | 9.15 | 9.19 | 9.25 | 9.25 | 9.31 | 9.39 | ||
| DM200HE | Q冷量(Kw) | 30 | 15.46 | 17.85 | 21.56 | 26.67 | 31.79 | 37.81 | 45.61 |
| 40 | 11.09 | 14.75 | 19.06 | 22.99 | 27.48 | 33.36 | 38.54 | ||
| 50 | 8.97 | 11.56 | 13.24 | 17.11 | 22.02 | 27.45 | 32.49 | ||
| P功率 (Kw) | 30 | 5.99 | 6.71 | 6.62 | 6.57 | 6.68 | 7.08 | 7.91 | |
| 40 | 7.65 | 8.77 | 8.81 | 8.85 | 8.89 | 8.93 | 8.98 | ||
| 50 | 9.67 | 9.98 | 10.88 | 10.91 | 10.98 | 11.01 | 11.07 | ||
Joto la kuyeyuka. -6.7°C,Kijoto cha Kupunguza. 48.9°C, gesi inayorudisha Joto 4.4°C, bila kupozwa kupita kiasi.
'2–12HP' inarejelea safu ya uwezo wa kupoeza wa kishinikiza (nguvu 2 za farasi hadi 12). Chagua kulingana na mzigo wako wa kupoeza: (1) 2–5HP kwa programu ndogo za kibiashara (kwa mfano, vipozezi vya duka, ofisi ndogo ya AC); (2) 6–9HP kwa matumizi ya kiwango cha wastani (kwa mfano, vipozezi vya kutembea kwenye mgahawa, kumbi za maonyesho ya rejareja); (3) 10–12HP kwa mifumo mikubwa zaidi (kwa mfano, hifadhi ya baridi ya ukubwa wa kati, jengo la kibiashara la AC).
Mfululizo wa DMZL hutoa: (1) Operesheni ya chini ya kelele (≤65dB), yanafaa kwa maeneo yenye kelele; (2) muundo wa kompakt, kuokoa nafasi ya ufungaji; (3) Ufanisi wa juu wa nishati (COP ≥3.8 kwa hali ya kawaida); (4) Pedi zilizojumuishwa za kuzuia mtetemo ili kupunguza kelele ya kimitambo na kupanua maisha ya sehemu.
Imeundwa kwa matumizi ya kibiashara kutokana na uwezo wake wa 2–12HP (AC ya makazi kwa kawaida hutumia vibandiko vya kusogeza vya 1–3HP). Hata hivyo, miundo ya 2–3HP inaweza kutumika kwa nafasi kubwa za makazi (kwa mfano, majengo ya kifahari) au mifumo ya AC ya vyumba vingi, mradi mfumo una ukubwa wa kutosha kwa mzigo wa kupoeza wa jengo.