| iwm | |
|---|---|
| , | |
Gobollada leh kheyraadka biyaha xaddidan ama codsiyada heerkulka hooseeya ee dibadda, qaboojiyaha qaboojiyaha (-5 ~ -40 ℃) waxay meesha ka saaraysaa baahida biyaha, xallinta dhibcooyinka xanuunka ee muhiimka ah:
Silsilad qabow oo meel fog ka fog : Waxay ku kordhisaa baabuurta qabow ee wareega iyo kaydinta ku meel gaadhka ah ee saxaraha ama meelaha buuraleyda ah, iyadoo ilaalinaysa -15~-40℃ cuntooyinka barafaysan iyo tallaalada.
Qalabka Warshadaha ee Dibadda : Qaboojiya qolalka tijaabada heerkulka hooseeya (tusaale, qaybaha baabuurta) iyo unugyada qaboojinta bannaanka, iyagoo u adkeysanaya heerkulka jawiga ugu hooseeya -10℃.
Tijaabooyinka Qoto-qabow ee Shaybaadhka : Waxay taageertaa shaybaadhka sayniska maadada u baahan -20 ~ -35 ℃ ee tijaabinta cryogenic, hubinta xasilloonida heerkulka ± 0.3℃ saxsanaanta.

Qaboojiyaha Waxqabadka Sare : FNHM/FNVT-condensers-taxane hawo qaboojiyeyaal leh qulqulka hawo weyn (6000 ~ 36000 m³ / h) waxay hubisaa daadinta kulaylka wax ku ool ah xitaa heerkulka deegaanka hoose.
Soo-gaadhe-lagu-dhisan : 6 ~ 45L qaataha waxa ay ku kaydiyaan qaboojiyaha, xasilinta hawlgalka nidaamka iyo yaraynta baahiyaha buuxinta ee joogtada ah—muhiim u ah goobaha fogfog.
Jirka Compressor : Ku shub birta leh rinjiga cimiladu, roobka, boodhka, iyo shucaaca UV ee isticmaalka dibadda; nolosha adeeggu waxay kordhisaa ilaa 12 sano xaaladaha adag.
Matoorada Fanka : Matoorrada torque-ga sarreeya (ku habboon 380 ~ 480V / 50 ~ 60Hz) waxay si habsami leh ugu shaqeeyaan -35℃, oo leh xajisyo jajab ah oo hooseeya oo yareynaya soo noqnoqoshada dayactirka.
Rakibaadda Goobta : Injineerada waxay u safraan meelo fogfog si loo rakibo, iyagoo hubinaya in kondenser-ka si sax ah loo waafajiyo jihada dabaysha si loo kordhiyo kuleylka kuleylka.
Tababarka Dayactirka : Tababar bilaash ah oo loogu talagalay shaqaalaha goobta jooga ee ku saabsan nadiifinta qaboojiyaha (si looga saaro boodhka/barafka) iyo hubinta heerarka qaboojiyaha-muhiim u ah waxqabadka unugga qaboojinta.
Gaadhida Qaybaha Daboolka : Qaybaha kaydka degdega ah (tusaale, marawaxada, kombaresarada) waxaa lagu soo raray DHL/FedEx, iyadoo 3-maalmood la geynayo wadamada intooda badan.
Hantidhawrka Tamarta : Adeegga xisaabinta tamarta sanadlaha ee ikhtiyaarka ah si loo wanaajiyo cabbirrada shaqada (tusaale, xawaaraha marawaxada, heerkulka qaboojinta) loona yareeyo kharashyada tamarta.
| Qaabka | Awood | Uumi-baxa | DeegaankaTemp. | Condenser | Cabirka (mm) | Cabbirka Rakibaadda (mm) | Dhuumaha isku xidha (φ :mm) | Miisaanka (kg) | |||||
| Tilmaamid | Socodka hawada (m³/h) | Qaabka | A | B | C | E | F | Nuugista | Dareeraha | ||||
| 4YD-3.2 | 380 ~ 420V-3PH-50Hz | -5~-40℃ | -10 ~ -35 ℃ | 1.7 | SLKD-003/B | 827 | 330 | 660 | 500 | 280 | 22 | 12 | 138 |
| 4YD-4.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 28 | 12 | 143 | |||
| 4YD-5.2 | 2.6 | SLKD-005/B1 | 827 | 330 | 660 | 500 | 280 | 28 | 12 | 146 | |||
| 4YD-8.2 | 4.9 | SLKD-010/B1 | 1127 | 330 | 715 | 800 | 280 | 35 | 16 | 205 | |||
| 4YD-10.2 | 4.9 | SLKD-010/B1 | 1127 | 330 | 715 | 800 | 280 | 35 | 16 | 219 | |||
| 4VD-15.2 | 7.6 | SLKD-015/B1 | 1250 | 380 | 760 | 900 | 330 | 42 | 22 | 304 | |||
| 4VD-20.2 | 8.9 | SLKD-020/B1 | 1250 | 380 | 760 | 900 | 330 | 54 | 22 | 317 | |||
| 6WD-30.2 | 12.2 | SLKD-030/B1 | 1650 | 380 | 810 | 1100 | 330 | 54 | 22 | 378 | |||
| 6WD-40.2 | 18.3 | SLKD-040/B1 | 1621 | 380 | 810 | 1100 | 330 | 54 | 28 | 402 | |||
| Qaabka | Heerkulka qaboojinta | Awoodda Qaboojinta Qo (W) Isticmaalka Korontada Pe(kW) | |||||||||||
| Heerkulka uumi-baxa ℃ | |||||||||||||
| 7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | -35 | -40 | |||
| BFS51 | 30 | Qo | 24000 | 22200 | 18600 | 15400 | 12600 | 10200 | 8500 | 6700 | 5300 | 4000 | 3000 |
| 40 | Qo | 20400 | 18900 | 15800 | 13100 | 10700 | 8700 | 7200 | 5700 | 4500 | 3400 | 2600 | |
| BFS81 | 30 | Qo | 31400 | 28700 | 24000 | 20000 | 16400 | 13400 | 10700 | 8500 | 6500 | 4900 | 3700 |
| 40 | Qo | 26400 | 24100 | 20200 | 16800 | 13800 | 11300 | 9000 | 7100 | 5500 | 4200 | 3100 | |
| BFS101 | 30 | Qo | 44800 | 44200 | 35100 | 29000 | 23900 | 19400 | 15600 | 12300 | 9500 | 7200 | 5300 |
| 40 | Qo | 38100 | 35600 | 29800 | 24600 | 20300 | 16500 | 13200 | 10500 | 8100 | 6100 | 4500 | |
| BFS151 | 30 | Qo | 69000 | 64500 | 54300 | 45200 | 37300 | 30500 | 25600 | 19600 | 15300 | 11700 | 8900 |
| 40 | Qo | 58700 | 54800 | 46200 | 38400 | 31700 | 25900 | 21800 | 16700 | 13000 | 9900 | 7500 | |
| Iyada oo ku saleysan heerkulka gaaska nuugista 20 ℃, 50Hz, iyada oo aan qaboojin dareere ah. | |||||||||||||
| Qaboojin dheeri ah ama heerkulka gaaska nuugid xaddidan. | |||||||||||||
| Qaboojin dheeri ah iyo nidaamka CIC. | |||||||||||||
S: Qalabku si lama filaan ah ayuu u xidhaa inta lagu jiro hawlgalka, isagoo muujinaya 'ilaalinta moduleka oo shaqaynaysa'. Maxaa la sameeyaa?
J: Marka hore, hubi sababta keentay kulaylka matoorka (tusaale, kulaylka oo xumaada, culeys xad dhaaf ah). Dayactir ka dib marka la aqoonsado sababta (tusaale, nadiif ah godadka daadinta kulaylka, yareyso culeyska), ka dibna dib u bilow qalabka.
S: Kadib markii meesha laga saaro kuleyliyaha mootada, qalabku wali wuu damayaa 'ilaalinta unugga kontoroolka otomaatiga ah'. Maxaa loo baahan yahay in la baaro?
J: Diirada saar si aad u hubiso xuduudaha dejinta ee qaybaha kantaroolka, sida in heerka culayska xad dhaafka ah iyo ilaalinta heerkulku ay yihiin kuwo aan caadi ahayn. Ku hagaaji halbeegyada caadiga ah oo tijaabi.
S: Haddii qalabku uu si joogto ah u kiciyo ilaalinta oo uu xidho, waa maxay tallaabooyinka ka hortagga ah ee la qaadayo marka laga reebo cillad-bixinta?
J: Si joogto ah u baadh heerka hawlgalinta qaybaha iyo unugyada xakamaynta, nadiifi siigada, oo xidh fiilooyinka si aad uga fogaato kicinta beenta ah ee ilaalinta sababtoo ah qaybta gabowga ama xidhiidhka liita.