Aantal keren bekeken: 0 Auteur: Site-editor Publicatietijd: 31-03-2026 Herkomst: Locatie
Model |
Verplaatsing 60/50Hz m³/uur |
Stappencontrole (%) |
Traploze regeling (%) |
Nominale PK 60Hz |
Nominale PK 50Hz |
Vi |
Beginnen |
Spanning (V) |
Isolatie |
Bescherming |
Olievulling L |
Oliekachel W |
Hydrostatische test kg/cm²G |
Netto Gewicht kg |
RC2-100A |
118/98 |
33, 66, 100 |
33~100 |
23 |
19 |
- |
DOL/PWS |
208/220/230/380/400/415/440/460/480/575 |
Klasse F |
PTC |
7 |
150/300 |
28 |
280 |
RC2-140A |
165/137 |
33, 66, 100 |
33~100 |
32 |
26 |
- |
DOL/PWS |
208/220/230/380/400/415/440/460/480/575 |
Klasse F |
PTC |
7 |
150/300 |
28 |
280 |
RC2-180A |
216/180 |
33, 66, 100 |
33~100 |
42 |
35 |
- |
DOL/PWS |
208/220/230/380/400/415/440/460/480/575 |
Klasse F |
PTC |
7 |
150/300 |
30 |
300 |
RC2-200A |
233/193 |
25, 50, 75, 100 |
25~100 |
45 |
37 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
8 |
150/300 |
42 |
420 |
RC2-230A |
277/230 |
35, 50, 75, 100 |
35~100 |
53 |
44 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
14 |
150/300 |
150/300 |
540 |
RC2-260A |
309/257 |
25, 50, 75, 100 |
25~100 |
59 |
49 |
2,2/2,6/3,0/3,5/4,8 |
Y-△ |
380/400/415 |
Klasse F |
PTC |
14 |
150/300 |
42 |
545 |
RC2-300A |
352/293 |
25, 50, 75, 100 |
25~100 |
67 |
56 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
16 |
150/300 |
- |
590 |
RC2-310A |
371/308 |
35, 50, 75, 100 |
35~100 |
71 |
59 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
16 |
150/300 |
- |
575 |
RC2-340A |
407/339 |
35, 50, 75, 100 |
35~100 |
77 |
64 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
16 |
150/300 |
- |
600 |
RC2-370A |
440/366 |
35, 50, 75, 100 |
35~100 |
84 |
70 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
16 |
150/300 |
- |
610 |
RC2-410A |
490/407 |
25, 50, 75, 100 |
25~100 |
93 |
78 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
16 |
150/300 |
- |
730 |
RC2-470A |
567/471 |
25, 50, 75, 100 |
25~100 |
108 |
90 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
18 |
150/300 |
- |
800 |
RC2-510A |
611/508 |
35, 50, 75, 100 |
35~100 |
117 |
98 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
20 |
150/300 |
150/300 |
760 |
RC2-550A |
660/549 |
25, 50, 75, 100 |
25~100 |
126 |
105 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
23 |
150/300 |
- |
820 |
RC2-580A |
702/583 |
35, 50, 75, 100 |
35~100 |
131 |
109 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
20 |
150/300 |
- |
805 |
RC2-620A |
745/619 |
35, 50, 75, 100 |
35~100 |
137 |
114 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
23 |
150/300 |
- |
850 |
RC2-710A |
858/713 |
35, 50, 75, 100 |
35~100 |
158 |
131 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
28 |
150/300 |
- |
1100 |
RC2-790A |
952/791 |
30, 50, 75, 100 |
30~100 |
175 |
146 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
28 |
150/300 |
- |
1140 |
RC2-830A |
993/825 |
30, 50, 75, 100 |
30~100 |
183 |
152 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
28 |
150/300 |
- |
1150 |
RC2-930A |
1117/929 |
35, 50, 75, 100 |
35~100 |
212 |
176 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
28 |
150/300 |
- |
1180 |
RC2-1020A |
1223/1017 |
25, 50, 75, 100 |
25~100 |
227 |
189 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
40 |
150/300 |
- |
1500 |
RC2-1130A |
1350/1122 |
25, 50, 75, 100 |
25~100 |
248 |
206 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
40 |
150/300 |
- |
1520 |
RC2-1270A |
1521/1268 |
25, 50, 75, 100 |
25~100 |
286 |
238 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
53 |
150/300 |
- |
2100 |
RC2-1530A |
1847/1539 |
25, 50, 75, 100 |
25~100 |
331 |
275 |
- |
Y-△ |
380/400/415 |
Klasse F |
PTC |
53 |
150/300 |
- |
2200 |