IOS Certificate Tube Ice Compressor - Semi-Hermetic Reciprocating Compressor R22 R404A R134A R507A 4VD-15.2-4VG-30.2 – Daming Refrigeration Technology Detail:
1. ZheJiang DaMing Refrigeration Technology Co., Ltd. Profile
- Business Type: We are Manufacturer/Factory/Plant
- Main Products: compressor ,compressor unit .(reciprocating compressor, scroll compressor, screw compressor)
- Number of Employees: 300+
- Year of Establishment: 1990s
- Management System Certification: ISO 9001
- Location: ZheJiang, China (Mainland)
2. Basic Information
- Series: 4VD-15.2-4VG-30.2 Explanation of model designation
- Compressor Body Material: Iron 4/6 ———————Cylinders
- Application : Refrigeration S ———————-Model
- Refrigeration gas: R22, R404A,R134A,R507A 15 ———————–Horse Power
- Input Voltage: 3Ф 380V-420V/50HZ;440V-480V/60HZ 1 ———————–Series Code
- Origin: Zhejiang, China D/G———————D for Low Temp;G for mid & High Temp
- Specification: CE, CCC,ISO9001
3. Application Limits ( Suction Gas Temperature 20°C)
R404A & R507A
R407C
R22
To —— Evaporating temperature(°C)
Toh —- Suction gas temperature(°C)
Toh —- Suction super heat(K)
Tc ——-Condensing temperature(°C)
Additional cooling
Additional cooling&limited suction gas temperature
Additional cooling&liquid injection cooling system
4.Product Details
4.1 Key Specifications/Special Features -Technical Data Sheet
Model | NominalPower
HP/KW |
Displacementm³/h 50Hz | Number ofCylinders×Diameter×Stoke | Exhaust & Suction Valve mm/IN | Oil Volume(L) | Power V/φ/Hz | Electrical Parameter | Crankcase Heater(220V)W | Oil SupplyMethod | Weight(Including Oil)
Kg |
||
DLExhaust Valve | SLSuction Valve | Max OperatingCurrent(A) | Starting/ LockedCurrent(A) | |||||||||
4VD-15.2 | 15/10.5 | 73.7 | 4×φ70×55 | φ28 | φ42 | 4 | 380-420YY/3/50 440-480YY/3/60 | 31 | 81/132 | 140 | Forced-lubrication | 183 |
4VG-25.2 | 25/18.5 | 73.7 | 4×φ70×55 | φ28 | φ54 | 4.5 | 45 | 116/193 | 140 | 203 | ||
4VD-20.2 | 20/15 | 84.6 | 4×φ75×55 | φ28 | φ54 | 4.5 | 37 | 97/158 | 140 | 192 | ||
4VG-30.2 | 30/22 | 84.6 | 4×φ75×55 | φ28 | φ54 | 4.5 | 53 | 135/220 | 140 | 206 |
4.2 Refrigerating Performance – Cooling Capacity with R22
Model | Condensing Temperature℃ | Cooling Capacity Qo(W) Power Consumption Pe(kW) | |||||||||||||
Evaporating Temperature ℃ | |||||||||||||||
12.5 | 10 | 7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | -35 | -40 | |||
4VD-15.2 | 30 | Qo | 52300 | 42700 | 34450 | 27350 | 21300 | 16400 | 12000 | 8310 | |||||
Pe | 12.73 | 11.93 | 11.01 | 9.98 | 8.82 | 8.25 | 7.13 | 5.98 | |||||||
40 | Qo | 46850 | 38100 | 30500 | 24050 | 18500 | 13840 | 9800 | 6440 | ||||||
Pe | 14.91 | 13.81 | 12.56 | 11.19 | 9.76 | 8.67 | 7.30 | 5.90 | |||||||
50 | Qo | 41700 | 33700 | 26800 | 20900 | 15800 | 11500 | 7920 | 4970 | ||||||
Pe | 17.11 | 15.67 | 14.13 | 12.47 | 10.85 | 9.21 | 7.53 | 5.79 | |||||||
4VG-25.2 | 30 | Qo | 99300 | 91200 | 83600 | 76500 | 63700 | 52600 | 42950 | 34650 | 27500 | 21400 | 16260 | ||
Pe | 13.89 | 13.74 | 13.56 | 13.34 | 12.84 | 12.22 | 11.48 | 10.63 | 9.67 | 8.59 | 7.41 | ||||
40 | Qo | 89700 | 82300 | 75400 | 68900 | 57300 | 47150 | 38350 | 30800 | 24250 | 18670 | 13940 | |||
Pe | 16.75 | 16.47 | 16.16 | 15.82 | 15.05 | 14.17 | 13.18 | 12.07 | 10.85 | 9.52 | 8.08 | ||||
50 | Qo | 80500 | 73800 | 67600 | 61700 | 51100 | 41950 | 33950 | 27050 | 21100 | 16030 | ||||
Pe | 19.56 | 19.16 | 18.74 | 18.27 | 17.25 | 16.10 | 14.83 | 13.44 | 11.94 | 10.33 | |||||
4VD-20.2 | 30 | Qo | 60000 | 48950 | 39500 | 31400 | 24500 | 18940 | 13920 | 9670 | |||||
Pe | 14.64 | 13.67 | 12.63 | 11.51 | 10.29 | 9.65 | 8.40 | 7.10 | |||||||
40 | Qo | 53700 | 43700 | 35100 | 27750 | 21500 | 16080 | 11430 | 7530 | ||||||
Pe | 17.39 | 16.04 | 14.60 | 13.07 | 11.42 | 10.35 | 8.75 | 7.14 | |||||||
50 | Qo | 47800 | 38750 | 30950 | 24200 | 18350 | 13390 | 9230 | 5790 | ||||||
Pe | 20.10 | 18.40 | 16.65 | 14.89 | 13.14 | 11.23 | 9.19 | 7.06 | |||||||
4VG-30.2 | 30 | Qo | 114200 | 104800 | 96000 | 87800 | 73100 | 60400 | 49300 | 39800 | 31650 | 24700 | 18840 | ||
Pe | 16.42 | 16.23 | 16.01 | 15.74 | 15.11 | 14.33 | 13.44 | 12.45 | 11.36 | 10.21 | 9.00 | ||||
40 | Qo | 103000 | 94500 | 86500 | 79100 | 65700 | 54000 | 44000 | 35350 | 27950 | 21650 | 16330 | |||
Pe | 19.78 | 19.46 | 19.09 | 18.68 | 17.74 | 16.67 | 15.49 | 14.20 | 12.83 | 11.40 | 9.92 | ||||
50 | Qo | 92300 | 84600 | 77400 | 70700 | 58600 | 48100 | 39000 | 31200 | 24500 | 18810 | ||||
Pe | 23.40 | 22.90 | 22.30 | 21.70 | 20.40 | 19.04 | 17.57 | 16.05 | 11.49 | 12.91 | |||||
Based on 20℃ suction gas temperature,50Hz,without liquid subcooling. | |||||||||||||||
VARICOOL system,additional cooling,position of suction valve changed. | |||||||||||||||
Additional cooling or limited suction gas temperature. | |||||||||||||||
Additional cooling and CIC system. |
Refrigerating Performance - Cooling Capacity with R404A,R507A
Model | Condensing Temperature℃ | Cooling Capacity Qo(W) Power Consumption Pe(kW) | ||||||||||||
Evaporating Temperature ℃ | ||||||||||||||
7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | -35 | -40 | -45 | |||
4VD-15.2 | 30 | Qo | 58500 | 48400 | 39700 | 32200 | 25750 | 20250 | 15560 | 11630 | 8350 | |||
Pe | 15.78 | 14.84 | 13.79 | 12.63 | 11.40 | 10.10 | 8.77 | 7.43 | 6.10 | |||||
40 | Qo | 49850 | 41150 | 33600 | 27100 | 21500 | 16730 | 12660 | 9240 | 6380 | ||||
Pe | 18.16 | 16.80 | 15.34 | 13.82 | 12.25 | 10.65 | 9.05 | 7.47 | 5.93 | |||||
50 | Qo | 33950 | 27600 | 22050 | 17330 | 13270 | 9820 | 6920 | ||||||
Pe | 18.50 | 16.67 | 14.80 | 12.91 | 11.03 | 9.17 | 7.37 | |||||||
4VG-25.2 | 30 | Qo | 90700 | 83200 | 69700 | 57900 | 47750 | 38950 | 31350 | 24800 | 19210 | 14460 | 10460 | |
Pe | 16.14 | 16.07 | 15.72 | 15.14 | 14.36 | 13.41 | 12.32 | 11.11 | 9.81 | 8.46 | 7.08 | |||
40 | Qo | 77400 | 71000 | 59500 | 49400 | 40650 | 33000 | 26450 | 20800 | 15930 | 11800 | 8320 | ||
Pe | 19.56 | 19.22 | 18.37 | 17.32 | 16.11 | 14.76 | 13.31 | 11.78 | 10.20 | 8.60 | 7.00 | |||
50 | Qo | 64500 | 59100 | 49500 | 41000 | 33600 | 27200 | 21600 | 16830 | 12740 | 9260 | 6340 | ||
Pe | 22.78 | 22.18 | 20.84 | 19.33 | 17.71 | 15.98 | 14.18 | 12.34 | 10.49 | 8.65 | 6.86 | |||
4VD-20.2 | 30 | Qo | 67100 | 55500 | 45400 | 36750 | 29350 | 23000 | 17600 | 13060 | 9260 | |||
Pe | 18.22 | 17.12 | 15.89 | 14.55 | 13.12 | 11.62 | 10.08 | 8.53 | 6.97 | |||||
40 | Qo | 57200 | 47300 | 38700 | 31200 | 24800 | 19250 | 14540 | 10540 | 7160 | ||||
Pe | 20.94 | 19.36 | 17.68 | 15.93 | 14.13 | 12.30 | 10.47 | 8.65 | 6.89 | |||||
50 | Qo | 38750 | 31650 | 25450 | 20100 | 15480 | 11510 | 8120 | ||||||
Pe | 21.25 | 19.15 | 17.02 | 14.87 | 12.73 | 10.63 | 8.60 | |||||||
4VG-30.2 | 30 | Qo | 103800 | 95300 | 79900 | 66500 | 54900 | 44900 | 36250 | 28800 | 22450 | 17040 | 12480 | |
Pe | 19.21 | 19.07 | 18.57 | 17.81 | 16.84 | 15.70 | 14.41 | 13.02 | 11.57 | 10.09 | 8.61 | |||
40 | Qo | 89100 | 81800 | 68600 | 57000 | 47000 | 38250 | 30700 | 24200 | 18610 | 13860 | 9850 | ||
Pe | 23.37 | 22.88 | 21.73 | 20.38 | 18.88 | 17.26 | 15.56 | 13.81 | 12.06 | 10.33 | 8.68 | |||
50 | Qo | 74300 | 68200 | 57100 | 47400 | 38900 | 31500 | 25100 | 19580 | 14840 | 10810 | 7410 | ||
Pe | 27.01 | 26.20 | 24.46 | 22.58 | 20.60 | 18.56 | 16.50 | 14.45 | 12.45 | 10.54 | 8.76 | |||
Based on 20℃ suction gas temperature,50Hz,without liquid subcooling. | ||||||||||||||
Additional cooling or limited suction gas temperature. | ||||||||||||||
Additional cooling and CIC system. |
Refrigerating Performance - Cooling Capacity with r134a
Model | Condensing Temperature℃ | Cooling Capacity Qo(W) Power Consumption Pe(kW) | |||||||||||
Evaporating Temperature ℃ | |||||||||||||
12.5 | 10 | 7.5 | 5 | 0 | -5 | -10 | -15 | -20 | -25 | -30 | |||
4VD-15.2 | 30 | Qo | 69100 | 62800 | 57000 | 51600 | 49150 | 33700 | 26700 | 20850 | 15920 | 11840 | 8500 |
Pe | 10.40 | 10.07 | 9.74 | 9.41 | 8.74 | 8.07 | 7.38 | 6.67 | 5.95 | 5.20 | 4.42 | ||
40 | Qo | 61300 | 55700 | 50400 | 45600 | 37000 | 29600 | 23350 | 18100 | 13700 | 10060 | 7080 | |
Pe | 12.46 | 11.93 | 11.43 | 10.93 | 9.97 | 9.04 | 8.13 | 7.23 | 6.32 | 5.39 | 4.44 | ||
50 | Qo | 54100 | 49050 | 44400 | 40100 | 32400 | 25800 | 20250 | 15570 | 11660 | 8430 | 5800 | |
Pe | 14.24 | 13.54 | 12.87 | 12.22 | 10.99 | 9.81 | 8.69 | 7.59 | 6.51 | 5.43 | 4.34 | ||
4VG-25.2 | 50 | Qo | 54100 | 49050 | 44400 | 40100 | 32400 | 25800 | 20250 | 15570 | 11660 | ||
Pe | 13.77 | 13.13 | 12.52 | 11.92 | 10.78 | 9.68 | 8.62 | 7.58 | 6.55 | ||||
60 | Qo | 47100 | 42700 | 38600 | 34800 | 28000 | 22200 | 17320 | 13190 | 9760 | |||
Pe | 15.04 | 14.27 | 13.53 | 12.81 | 11.44 | 10.13 | 8.89 | 7.69 | 6.53 | ||||
70 | Qo | 40250 | 36450 | 32900 | 29600 | 23750 | 18740 | 14500 | 10940 | 7980 | |||
Pe | 16.09 | 15.21 | 14.36 | 13.53 | 11.96 | 10.48 | 9.07 | 7.74 | 6.45 | ||||
4VD-20.2 | 30 | Qo | 78500 | 71400 | 64800 | 58600 | 47700 | 38350 | 30450 | 23800 | 18190 | 13560 | 9770 |
Pe | 12.45 | 12.15 | 11.83 | 11.50 | 10.78 | 10.00 | 9.16 | 8.26 | 7.31 | 6.32 | 5.28 | ||
40 | Qo | 69700 | 63300 | 57400 | 51900 | 42100 | 33750 | 26650 | 20700 | 15700 | 11570 | 8190 | |
Pe | 14.65 | 14.14 | 13.62 | 13.09 | 12.03 | 10.95 | 9.85 | 8.73 | 7.59 | 6.44 | 5.28 | ||
50 | Qo | 61500 | 55800 | 50500 | 45650 | 36950 | 29500 | 23200 | 17870 | 13430 | 9760 | 6770 | |
Pe | 16.67 | 15.93 | 15.20 | 14.48 | 13.06 | 11.67 | 10.31 | 8.97 | 7.66 | 6.37 | 5.10 | ||
4VG-30.2 | 50 | Qo | 61500 | 55800 | 50500 | 45650 | 36950 | 29500 | 23200 | 17870 | 13430 | ||
Pe | 16.09 | 15.42 | 14.76 | 14.10 | 12.79 | 11.50 | 10.22 | 8.94 | 7.67 | ||||
60 | Qo | 53700 | 48650 | 44000 | 39700 | 32000 | 25450 | 19890 | 15210 | 11300 | |||
Pe | 17.65 | 16.80 | 15.96 | 15.14 | 13.54 | 11.99 | 10.49 | 9.03 | 7.60 | ||||
70 | Qo | 45900 | 41600 | 37600 | 33850 | 27200 | 21550 | 16720 | 12680 | 9320 | |||
Pe | 19.22 | 18.16 | 17.14 | 16.15 | 14.25 | 12.46 | 10.75 | 9.12 | 7.55 | ||||
Suction gas temperature 20℃,50Hz,without liquid subcooling. | |||||||||||||
Additional cooling or limited suction gas temperature. |
4.3 Processing Features
The compressors of Daming suit different working condition and refrigerants,and could maximally satisfy your requirements for the refrigerating system.
Developed technology,compact dimension ,Small volume and space .
High precision machining to ensure the compressor confirm with the standard ,CNC processing center ,Concentricity due to specific processing technology ,minimal dead space .
Steady operation,small vibracation and low noise ,Excellent stability .
Refrigerant like R22 and R404 are adopted to protect the environment ,For mid & low temperature application .
Electrical motor protect device ,PTC sensor .
Wear resistant driver gear ,Chrome plated piston rings and aluminium pistons ,Hardened crank-shaft ,Low friction bearing set .
Efficient valve plate design,high refrigerating capacity and low energy consumption ,Efficient compression rate ,Valve reed made of imported impact resistant spring steel .
General spare parts,convenient for maintenance.
4.4 Cross Reference (Application Limits )
Cross Reference |
||||
Item Description |
Daming Model |
Copeland Model |
Bitzer Model |
Displacement (KW) |
2 cylinders |
BFS31 |
C-0300 |
12.2 |
|
BFS41 |
C-0400 |
14.7 |
||
BFS51 |
C-0500 |
18.4 |
||
BFS81 |
C-0800 |
26.6 |
||
BFS101 |
C-1000 |
36 |
||
3 cylinders |
BFS151 |
C-1500 |
54 |
|
4 cylinders |
4S151D |
4SLW-1500 |
73.6 |
|
4S251G |
4SHH-2500 |
73.6 |
||
4S201D |
4STW-2000 |
84.5 |
||
4S301G |
4STH-3000 |
84.5 |
||
6 cylinders |
6S251D |
6SLW-2500 |
110.5 |
|
6S351G |
6SHH-3500 |
110.5 |
||
6S321D |
6STW-3200 |
126.8 |
||
6S401G |
6SJH-4000 |
126.8 |
||
6S401D |
6SUW-4000 |
151.6 |
||
6S501G |
6SKH-5000 |
151.6 |
||
Small size 2 cylinders |
2YD-2.2 |
2DC-2.2 |
13.5 |
|
2YG-3.2 |
2DC-3.2 |
13.5 |
||
2YD-3.2 |
2CC-3.2 |
16.2 |
||
2YG-4.2 |
2CC-4.2 |
16.2 |
||
Small size 4 cylinder ( hexagon shape) |
4YD-3.2 |
4FC-3.2 |
18.1 |
|
4YG-5.2 |
4FC-5.2 |
18.1 |
||
4YD-4.2 |
4EC-4.2 |
22.7 |
||
4YG-6.2 |
4EC-6.2 |
22.7 |
||
4YD-5.2 |
4DC-5.2 |
26.84 |
||
4YG-7.2 |
4DC-7.2 |
26.84 |
||
4YD-6.2 |
4CC-6.2 |
32.48 |
||
4YG-9.2 |
4CC-9.2 |
32.48 |
||
Medium size 4 cylinders (hexagon shape ) |
4YD-8.2 |
4TCS-8.2 |
41.33 |
|
4YG-12.2 |
4TCS-12.2 |
41.33 |
||
4YD-10.2 |
4PCS-10.2 |
48.5 |
||
4YG-15.2 |
4PCS-15.2 |
48.5 |
||
4YD-12.2 |
4NCS-12.2 |
56.25 |
||
4YG-20.2 |
4NCS-20.2 |
56.25 |
||
Large 4 cylinders |
4VD-15.2 |
4H-15.2 |
73.6 |
|
4VG-25.2 |
4H-25.2 |
73.6 |
||
4VD-20.2 |
4G-20.2 |
84.5 |
||
4VG-30.2 |
4G-30.2 |
84.5 |
||
Large 6 cylinders |
6WD-25.2 |
6H-25.2 |
110.5 |
|
6WG-35.2 |
6H-35.2 |
110.5 |
||
6WD-30.2 |
6G-30.2 |
126.8 |
||
6WG-40.2 |
6G-40.2 |
126.8 |
||
6WD-40.2 |
6F-40.2 |
151.6 |
||
6WG-50.2 |
6F-50.2 |
151.6 |
||
Double stage |
6WDS-20.2 |
S6H-20.2 |
110.5 |
|
6WDS-25.2 |
S6G-25.2 |
126.8 |
||
6WDS-30.2 |
S6F-30.2 |
151.6 |
4.5 Compressor Dimensional drawing
4.6 Packaging & Shipment
- FOB Port: Ningbo Lead Time:15- 30 days
- Packaging Size: 49*44*15 cm Net weight: 62 kg +
- Units per Export Carton:1 Gross weight: 70 kg +
- Dimensions per Unit:193 × 94 × 87 Centimeters
- Weight per Unit:117 Kilograms
- Export Carton Weight: 117 Kilograms
- Export Carton Dimensions L/W/H:193 × 94 × 87 Centimeters
5. Payment & Delivery
- Payment Method: Advance TT, T/T, L/C.
- Delivery Details: within 30-50 days after receiving your full payment .
3.7 Primary Competitive Advantage
- Small Orders Accepted Brand-name Parts Country of Origin
- Distributorships Offered Electronic Link Experienced Staff
- Form A Green Product Cost-effective
- International Approvals Military Specifications Standard Packaging
- Good Price Product Features Product Performance
- Prompt Delivery Quality Approvals Reputation
- Provide Good Service Sample Available Customized
- We have over 30 years of professional experience as a manufacturer of semi-hermetic compressor , scroll compressor , screw compressor ,condensing unit .
- We make the compressor according your usage
- We have strong researching and developing team to meet your requirement.
- There are lot of raw material suppliers around our factory, our factory in Zhejiang
- We supply high quality compressor for many world companies
- Our factory got ISO 9001 and apply CE certificate, importantly we have factory which bigger workshop over 20000sq meters .
- Small trial orders can be accepted, sample is available .
- Our price is reasonable and keep top quality for every clients.
Product detail pictures:

Related Product Guide:
What Are the Advantages of Using a Reciprocating Compressor?
Reciprocating Compressors – Operations and Applications Related to the Product
To fulfill the customers' over-expected fulfillment , we have now our solid staff to deliver our greatest general assistance which includes internet marketing, product sales, creating, manufacturing, excellent controlling, packing, warehousing and logistics for IOS Certificate Tube Ice Compressor - Semi-Hermetic Reciprocating Compressor R22 R404A R134A R507A 4VD-15.2-4VG-30.2 – Daming Refrigeration Technology, The product will supply to all over the world, such as: California, Kuwait, belarus, All the imported machines effectively control and guarantee the machining precision for the products. Besides, we have a group of high-quality management personnels and professionals, who make the high-quality products and have the ability to develop new products to expand our market home and abroad. We sincerely expect customers come for a blooming business for both of us.

The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly

-
China Cheap price Stationary Air Compressor - ...
-
Wholesale ODM Tent Air Condition System - Semi...
-
Lowest Price for Condenser Unit - DAMING SCROL...
-
Chinese Professional Refrigeration Unit For Car...
-
Professional Factory for 459cfm Compressor - D...
-
100% Original Factory Diesel Engine Driven Air ...