RFC6DS
RFC
The Double-Stage Semi-Hermetic Compressor RFC combines RFC’s expertise in quiet operation with advanced two-stage compression technology, delivering exceptional performance in ultra-low-temperature applications. This model addresses the key limitation of single-stage compressors—high discharge temperatures at low evaporation temperatures—by splitting compression into two stages, which reduces thermal stress on components and cuts energy use. Its compact design (15% smaller than other double-stage compressors of the same capacity) makes it suitable for space-constrained facilities, such as urban medical labs or small-scale frozen food plants, where deep cooling (down to -45℃) is required but floor space is limited. The semi-hermetic housing uses a gasket-sealed cover that prevents refrigerant leaks (leak rate < 0.1 g/year) and allows easy access for maintenance.

Two-Stage Compression: The low-pressure cylinder compresses refrigerant to an intermediate pressure of 0.32 MPa, then the high-pressure cylinder compresses it to 1.3 MPa (condensing pressure). This splits the total compression ratio into two smaller ratios (≤4:1 per stage), reducing valve wear and discharge temperature (kept below 85℃ at -35℃ evaporation).
Energy Efficiency: Achieves a COP of 1.9 at -35℃ evaporation temperature—this cuts energy costs by 18% compared to single-stage compressors of equivalent capacity (e.g., a single-stage 22 kW compressor uses 12.2 kW, while this model uses 11.6 kW). Over a year of 24/7 operation, this saves approximately 3,000 kWh.
Quiet Operation: Acoustic insulation glass wool around the cylinder block and optimized valve design reduce noise to ≤66 dBA—the lowest in its class for double-stage compressors. This makes it suitable for medical facilities (e.g., hospital labs) where quiet operation is critical for staff focus.
Comprehensive Protection: Equipped with oil level sensors (triggers alert if levels drop below 25%), high/low pressure switches (HP set to 1.5 MPa, LP set to 0.1 MPa), and phase protection (prevents motor damage from reverse phase or phase loss). All protections are linked to a digital controller that logs errors for troubleshooting.
Medical freezers for vaccine storage (-40℃): Stores COVID-19 vaccines, influenza vaccines, and other temperature-sensitive biologics, complying with CDC and FDA cold chain requirements (temperature monitoring every 10 minutes).
Industrial freeze-drying equipment: Cools freeze-dry chambers to -45℃ for pharmaceutical (e.g., protein powders) and food (e.g., instant coffee) applications, removing moisture via sublimation.
Deep-freeze cold storage (200-600 m³): Stores industrial raw materials (e.g., rubber compounds, metal powders) that require ultra-low temperatures to maintain stability, with capacity to handle 20+ tons of goods.
Seafood processing and storage facilities: Flash-cools freshly caught seafood (e.g., shrimp, scallops) from 10℃ to -25℃ in 45 minutes, preserving flavor and texture for export.
| RFC Model | Nominal Power HP/KW | Displacement m³/h@ 50Hz | Number of Cylinders ×Diameter×Stoke | Exhaust & Suction Valve mm/IN | Oil Volume L | Power V/φ/Hz | Electrical Parameter | Crankcase Heater (220V)W | Oil Supply Method | Weight (with lubricant) Kg | ||
| DL Exhaust Valve | SL Suction Valve | Max Operating Current (A) | Starting/ Locked Current (A) | |||||||||
| RFC4DS-12.2 | 12/8.8 | 42.3/27 | 4×φ75/60×55 | φ28 | φ35 | 4.5 | 380-420YY/3/50 440-480YY/3/60 | 24 | 69/113 | 140 | Forced-lubrication | 180 |
| RFC6DS-16.2 | 16/11.7 | 63.5/31.8 | 6×φ65/65×55 | φ35 | φ42 | 4.75 | 380-420YY/3/50 440-480YY/3/60 | 31 | 81/132 | 140 | Forced-lubrication | 209 |
| RFC6DS-20.2 | 20/15 | 110.5 | 6×φ70/70×55 | φ35 | φ42 | 4.75 | 380-420YY/3/50 440-480YY/3/60 | 37 | 97/158 | 140 | Forced-lubrication | 220 |
| RFC6DS-25.2 | 25/18.5 | 126.8 | 6×φ75/75×55 | φ35 | φ42 | 4.75 | 380-420YY/3/50 440-480YY/3/60 | 45 | 116/193 | 140 | Forced-lubrication | 233 |
| RFC6DS-30.2 | 30/22 | 151.6 | 6×φ82/82×55 | φ35 | φ42 | 4.75 | 380-420YY/3/50 440-480YY/3/60 | 53 | 135/220 | 140 | Forced-lubrication | 234 |
| Model | Condensing Temperature℃ | Cooling Capacity Qo(W) Power Consumption Pe(kW) | ||||||||||
| Evaporating Temperature ℃ | ||||||||||||
| -25 | -30 | -35 | -40 | -45 | -50 | -55 | -60 | -65 | -70 | |||
| RFC4DS-12.2 | 30 | Qo | 19480 | 16830 | 14270 | 11850 | 9640 | 7670 | 5980 | 4560 | 3400 | 2490 |
| Pe | 9.74 | 9.06 | 8.35 | 7.61 | 6.85 | 6.10 | 5.35 | 4.62 | 3.92 | 3.27 | ||
| 40 | Qo | 18910 | 16220 | 13680 | 11330 | 9220 | 7360 | 5760 | 4390 | 3250 | ||
| Pe | 11.05 | 10.23 | 9.37 | 8.49 | 7.60 | 6.72 | 5.85 | 5.01 | 4.22 | |||
| 50 | Qo | 18060 | 15460 | 13050 | 10840 | 8850 | 7090 | 5530 | 6640 | 4990 | ||
| Pe | 12.32 | 11.40 | 10.44 | 9.44 | 8.42 | 7.41 | 6.41 | 6.40 | 5.49 | |||
| RFC6DS-16.2 | 30 | Qo | 27600 | 23700 | 20100 | 16800 | 13750 | 11200 | 8650 | 6640 | 4990 | 3660 |
| Pe | 14.13 | 12.93 | 11.76 | 10.60 | 9.48 | 8.40 | 7.37 | 6.40 | 5.49 | 4.65 | ||
| 40 | Qo | 26500 | 22800 | 19330 | 16100 | 13170 | 10570 | 8320 | 6400 | 4780 | ||
| Pe | 16.00 | 14.58 | 13.21 | 11.90 | 10.63 | 9.42 | 8.26 | 7.15 | 6.10 | |||
| 50 | Qo | 25500 | 21900 | 18500 | 15430 | 12660 | 10200 | 8010 | ||||
| Pe | 17.83 | 16.23 | 14.68 | 13.20 | 11.78 | 10.41 | 9.10 | |||||
| RFC6DS-20.2 | 30 | Qo | 31900 | 27450 | 23300 | 19440 | 15910 | 12760 | 10020 | 7690 | 5770 | 4230 |
| Pe | 16.43 | 15.02 | 13.64 | 12.30 | 11.00 | 9.76 | 8.57 | 7.44 | 6.40 | 5.40 | ||
| 40 | Qo | 30600 | 26350 | 22350 | 18610 | 15230 | 12240 | 9640 | 7420 | 5540 | ||
| Pe | 18.53 | 16.90 | 15.32 | 13.79 | 12.33 | 10.92 | 9.57 | 8.29 | 7.07 | |||
| 50 | Qo | 29350 | 25200 | 21350 | 17810 | 14630 | 11800 | 9280 | ||||
| Pe | 20.63 | 18.79 | 17.01 | 15.30 | 13.65 | 12.07 | 10.55 | |||||
| RFC6DS-25.2 | 30 | Qo | 36200 | 31300 | 26600 | 22250 | 18220 | 14620 | 11480 | 8830 | 6630 | 4870 |
| Pe | 18.84 | 17.27 | 15.71 | 14.16 | 12.65 | 11.19 | 9.80 | 8.49 | 7.29 | 6.20 | ||
| 40 | Qo | 34900 | 30100 | 25500 | 21300 | 17420 | 14000 | 11040 | 8500 | 6350 | ||
| Pe | 21.27 | 19.40 | 17.60 | 15.85 | 14.16 | 12.55 | 11.00 | 9.52 | 8.13 | |||
| 50 | Qo | 33450 | 28750 | 24350 | 20350 | 16720 | 13490 | 10620 | ||||
| Pe | 23.71 | 21.58 | 19.35 | 17.56 | 15.67 | 13.85 | 12.10 | |||||
| RFC6DS-30.2 | 30 | Qo | 43400 | 37400 | 31750 | 26500 | 21700 | 17420 | 13690 | 10540 | 7920 | 5800 |
| Pe | 22.53 | 20.65 | 18.78 | 16.94 | 15.15 | 13.42 | 11.77 | 10.20 | 8.74 | 7.40 | ||
| 40 | Qo | 41500 | 35700 | 30300 | 25300 | 20700 | 16680 | 13170 | 10150 | 7590 | ||
| Pe | 25.20 | 23.10 | 21.01 | 18.96 | 16.95 | 15.00 | 13.14 | 11.37 | 9.72 | |||
| 50 | Qo | 39500 | 34000 | 28850 | 24100 | 19870 | 16060 | 12650 | ||||
| Pe | 28.07 | 25.69 | 23.33 | 21.01 | 18.75 | 16.57 | 14.49 | |||||
What is the maximum cooling capacity?
Delivers 22 kW of cooling capacity at -30℃ evaporation temperature (suitable for mid-sized deep freezers) and 18 kW at -35℃ (for ultra-low applications). Power consumption at -30℃ is 11.6 kW, with a current draw of 20 A (380V/50Hz).
How is the interstage pressure controlled?
An automatic pressure regulator maintains intermediate pressure within 0.3-0.4 MPa for optimal efficiency. If intermediate pressure exceeds 0.4 MPa (e.g., due to a clogged intercooler), the regulator vents excess pressure to the evaporator, preventing HP cylinder overload.
What are the installation requirements?
Requires a dedicated 380V/50Hz circuit with a minimum current rating of 30 A (to handle startup current). A clearance of 0.5 m around the unit is needed for ventilation (airflow ≥ 2 m/s) to dissipate heat. The unit must be mounted on a level surface (±0.5°) to avoid oil pooling.